12
12. Trouble shooting
Situation
Solution
Fault
Code
Fault Event Description
60
Current feedback into the
inverter is detected.
1. Restart the inverter.
2. If the problem remains, please contact
your installer.
71
The firmware version of each
inverter is not the same.
1. Update all inverter firmware to the
same version.
2. If the problem remains, please contact
your installer.
72
The output current of each
inverter is different.
1. Check if sharing cables are connected
well and restart the inverter.
2. If the problem remains, please contact
your installer.
80
CAN data loss
1. Check if communication cables are
connected well and restart the inverter.
2. If the problem remains, please contact
your installer.
81
Host data loss
82
Synchronization data loss
83
The battery voltage of each
inverter is not the same.
1. Make sure all inverters share same
groups of batteries together.
2. If the problem remains, please contact
your installer.
84
AC input voltage and frequency
are detected different
1. Check the utility wiring conncetion and
restart the inverter.
2. If the problem remains, please contact
your installer.
85
AC output current unbalance
1. Restart the inverter.
2. If the problem remains, please contact
your installer.
86
AC output mode setting is
different.
1. Switch off the inverter and check LCD
setting #28.
2. If the problem remains, please contact
your installer.
Przeglądanie stron 11
1 2 ... 7 8 9 10 11 12

Komentarze do niniejszej Instrukcji